Amtrol R Digital Control Manual

4/7/2018by

Save up to 35% off list price with US Water on the Amtrol Pressurizer System 15 GPM. Includes the Amtrol'R® Digital Control. Amtrol Manual. Your Guardian CP DIGITAL CONTROL has been carefully assembled and factory. The Product manual can be viewed at www.amtrol.com. Use proper safety equipment when.

• West Warwick, Rhode Island 02893 INDIRECT-FIRED WATER HEATERS MODELS COVERED: • WH-7 & 9 Classic Series • Top Down • RTR models • WHS Premier Series INSTALLER: LEAVE THIS MANUAL WITH THE OWNER IMPORTANT GENERAL SAFETY INFORMATION - ADDITIONAL SPECIFIC SAFETY ALERTS APPEAR IN THE FOLLOWING INSTRUCTIONS. Pre-Installation Checklist. Required Components and Accessories Checklist.

Amtrol R Digital Control Manual

WH-7 & 9 Classic Series Piping Installation. Top Down™ TD-Series Piping Installation. Ready-To-Run RTR-Series Piping Installation. WHS Premier Series Piping Installation. • SEE HEAT EXCHANGER PRESSURE DROP CHART TO DETERMINE PUMP HEAD REQUIREMENTS. Use this chart to select the proper circulator for your BOILERMATE If a steel hydropneumatic tank is in place, AMTROL properly sized EXTROL heat transfer problems can occur by causing air to be trapped in the heat exchanger. If the boiler system has.

• PIPING INSTALLATION DOMESTIC WATER PIPING 1. Thread the included ” brass tee onto the pipe marked COLD WATER. Screw the ” drain valve into the opposite end of the brass tee. Connect the cold water supply to the remaining port on the brass tee. • PIPING USING SEPARATE CIRCULATOR PUMP (RECOMMENDED) PIPING USING ZONE VALVE WITH EXISTING HEATING SYSTEM CIRCULATOR.

TOP DOWN™ TD-SERIES PIPING INSTALLATION DOMESTIC WATER PIPING 1. Connect the cold water supply to the pipe labeled COLD WATER 2. Connect the HOT WATER piping to the domestic hot water system. Make an 8-inch “heat trap” on the HOT WATER outlet as shown in the diagram. Globalisation And The Third World Pdf.

• PIPING USING SEPARATE CIRCULATOR PUMP (RECOMMENDED) PIPING USING ZONE VALVE WITH EXISTING HEATING SYSTEM CIRCULATOR. READY-TO-RUN RTR-SERIES PIPING INSTALLATION DOMESTIC WATER PIPING 1. Connect the cold water supply to the pipe labeled COLD WATER. Connect the HOT WATER piping to the domestic hot water system. Make an 8-inch “heat trap” on the HOT WATER outlet as shown in the diagram.

• PIPING MODELS WITH PRE-INSTALLED CIRCULATOR W/INTEGRAL FLOW CHECK. WHS PREMIER SERIES PIPING INSTALLATION DOMESTIC WATER PIPING 1. Thread the included brass tee onto the pipe marked COLD WATER.

Screw the drain valve into the opposite end of the brass 3. Connect the cold water supply to the remaining port on the brass tee 4. George Series 1-3 By Stephen And Lucy Hawking Programs here. • PIPING USING SEPARATE CIRCULATOR PUMP (RECOMMENDED) PIPING USING ZONE VALVE WITH EXISTING HEATING SYSTEM CIRCULATOR -11. • The Smart Control™ incorporates all the switching and temperature control functions necessary to control the BoilerMate™. The diagram below shows internal wiring and the associated functions.

After wiring is complete, insert the white thermistor (sensor) plug into the receptacle at the base of the Smart Control™. Select the plug marked CIRCULATOR or ZONE VALVE based on the application. Dsp True Speech Codec. • L8124 A & C L8124 B & D LOW LIMIT/ HIGH CIRCULATOR LIMIT L1 L2 L8148A HIGH LIMIT HONEYWELL L8148A BOILERMATE ® CIRCULATOR HONEYWELL L8124 A & C BOILERMATE ® CIRCULATOR HONEYWELL L8124 B & D L1 L2 BOILERMATE CIRCULATOR -13- BOILERMATE ®. • L8148J W TV LIMIT C1 C2 B1 B2 B3 L1 L2 L1 L2 L8148J W TV LIMIT C1 C2 B1 B2 B3 L1 L2 L1 L2 8J48A WHITE - RODGERS 8J48A WITH 24 VOLT GAS VALVE BOILERMATE JUNCTION BOX (PLACE A WIRE NUT OVER EACH WIRE NOT USED) BOILERMATE ®. • 8J48A WHITE - RODGERS 8J48A WITH SELF-GENERATING GAS VALVE L8124 A & C HEATING CIRCULATOR L8124 B & D HIGH LOW LIMIT/ LIMIT CIRCULATOR HEATING CIRCULATOR BOILERMATE ® CIRCULATOR PRIORITY WIRING HONEYWELL L8124 A & C BOILERMATE ® HONEYWELL L8124 B & D CIRCULATOR -15- BOILERMATE. • L8148A HIGH LIMIT L8148B HIGH LIMIT L8148J TP Z LIMIT C1 C2 B1 B2 BOILERMATE JUNCTION BOX PRIORITY WIRING BOILERMATE ® HONEYWELL L8148A CIRCULATOR L1 L2 BOILERMATE ® CIRCULATOR PRIORITY WIRING HONEYWELL L8148B BOILERMATE ® HONEYWELL L8148 J CIRCULATOR -16- ®. • L8148J TP Z LIMIT C1 C2 B1 B2 8J48A PRIORITY WIRING WHITE-RODGERS 8J48A WITH 24VOLT GAS VALVE 8J48A PRIORITY WIRING WHITE-RODGERS 8J48A WITH SELF-GENERATING GAS VALVE BOILERMATE JUNCTION BOX ORANGE ORANGE BLUE BLUE VIOLET VIOLET WHITE BLACK PRIORITY WIRING BOILERMATE ®.

• Typical Multi-Zone Relay Utilizing Post-Purge Feature Thermostat Inputs Priority or DHW Zone Zone Outputs BoilerMate Boiler Aquastat Circulator Typical Multi-Zone Relay 24V without Post-Purge Feature Thermostat Inputs Priority or DHW Zone Supply Zone Outputs BoilerMate Boiler Aquastat Circulator ORANGE ORANGE BLUE BLUE VIOLET. • The Smart Control™ features an error code designed to alert the user to the presence of water on the floor. This is useful to warn of a leaking boiler, water heater, etc., or to alert the owner to a leak in the basement. If equipped with the optional water. • To wire Dial Control models, select the appropriate diagram from the following pages.

Comments are closed.